Do you have a question about the BD Accuri C6 and is the answer not in the manual?
Sample Acquisition Rate | Up to 10, 000 events/second |
---|---|
Sample Flow Rate | 35 μL/min |
Operating Temperature | 15°C to 30°C |
Power Requirements | 100–240 VAC; 50/60 Hz |
Fluorescence Channels | 4 (FL1, FL2, FL3, FL4) |
Provides information on cytometer requirements, setup, maintenance, and troubleshooting.
Instructions for inspecting the cytometer upon receipt for signs of damage or mishandling.
Details technical specifications of the BD Accuri C6 Flow Cytometer, including lasers, optics, and performance.
Refers to a separate manual for comprehensive safety information and instrument limitations.
Discusses environmental and usage conditions for optimal cytometer performance.
Specifies the acceptable operating temperature range (15-30°C) and humidity (<80%).
Describes recommended placement and ventilation requirements for the cytometer on a lab bench.
Lists the recommended fluids and solutions for operation and cleaning of the instrument.
Provides contact information and website to obtain Material Safety Data Sheets (MSDS).
Identifies and illustrates the major components of the fluidics and optics subsystems of the cytometer.
Guides on initial setup of the computer, monitor, keyboard, and mouse for the cytometer.
Basic steps for setting up the computer, monitor, keyboard, and mouse according to manufacturer instructions.
Optimizes Windows 7 power and display settings for the BD Accuri C6 workstation.
Instructions to show hidden file extensions in Windows 7 for BD Accuri C6 software files.
Procedures for physically setting up the BD Accuri C6 Flow Cytometer, including cover and filter checks.
Details on filling reagent bottles and connecting fluidics harness to the cytometer and bottles.
Instructions for connecting the power supply and USB cables to the cytometer and computer.
Information on installing the BD Accuri C6 Software and the cytometer driver, if not pre-installed.
Step-by-step guide for installing the BD Accuri C6 Software using the provided CD.
Procedure for powering on the cytometer, initial fluidics flush, and validation.
Detailed steps for properly shutting down the BD Accuri C6 Flow Cytometer via software and power button.
Describes the system's automated maintenance reminders triggered by usage or time.
Procedure for cleaning the Sample Introduction Port (SIP) to remove clogs using a backflush cycle.
Instructions for cleaning the flow cell as part of regular maintenance or to correct performance issues.
Steps to purge the flow cell of debris using the unclog cycle function.
Procedure for a thorough flow cell cleaning cycle, including a soak period.
Details the process and timing for the cytometer's decontamination fluid cycle.
Procedure for running the cleaning fluid cycle to flush the system with cleaner fluid.
Steps to remove air from the fluidic system, relevant for first-time setup or after extended non-use.
Instructions for safely emptying the waste bottle daily or when prompted by the software.
Guidance on checking and refilling sheath, cleaning, and decontamination fluid bottles.
Steps for replacing the disk filters in the sheath, cleaner, and decontamination fluid bottles.
Procedure for checking fluidics lines for leaks, crimping, or dried residue.
Instructions for replacing the in-line sheath filter, recommended every two months.
Steps for replacing the peristaltic pump tubing for both sheath and waste pumps.
General guidelines for resolving common instrument issues, with contact info for persistent problems.
Procedure for cleaning and decontaminating the system, recommended for storage or service.
Information on the product's limited warranty period, coverage for software/firmware, and exclusions.
Information on the availability and details of purchasing extended warranty coverage for the product.
Contact details and locations for obtaining technical support in USA, Europe, Middle East, Africa, and Canada.
Information on how to order replacement parts and reagents, including regional office contacts.