6. PRE-OPERATION CHECKLIST
6.1. Follow the checklist below prior to using the machine each time.
6.1.1. Check that the engine oil is at the proper level.
6.1.2. Use SAE 15W40 Oil
6.1.3. Check the 2 handle thumbwheels making sure that they are tight and will not vibrate
loose.
6.1.4. Add fuel to the petrol tank.
6.1.5. Connect and tighten the garden hose to the water supply inlet connection, you will need a
hose adaptor (supplied).
6.1.6. Water MUST be turned on prior to starting the washer, pull the spray trigger to make sure
that water is moving the through the lines and out the nozzle without any leaks before starting the
machine.
6.1.7. Review the safety guidelines in the manual prior to starting the machine.
6.1.8. If you have any issues operating the pressure washer, call Aftersales on 01646 687880.
Always check the level of the engine and pump oil prior to starting the
washer. Top up oils to correct levels. Failure to do so could cause the
engine to seize if the oil is low or empty.
DO NOT start your pressure washer without the water supply turned on.
Failure to do so will result in damaging the pump from overheating and
void the warranty.
Page 14
6.1.9. The PE-5024HWEBGEN has an Oil Alert system which is designed to prevent engine
damage caused by an insufficient amount of oil in the crankcase. Before the oil level in
the crankcase can fall below a safe limit, the Oil Alert indicator (red) comes on and the
Oil Alert system will automatically stop the engine (the engine switch will remain in the
ON position).
If the engine stops and will not restart, check the engine oil level before
troubleshooting in other areas.