EasyManua.ls Logo

Becker Centronic TimeControl TC445-II - Advanced Settings and Customization; Holiday, Position, and Limit Settings

Becker Centronic TimeControl TC445-II
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
fr
en
de
nl

Automatic switching times for roller shutters and venetian blinds to be raised
and lower ed in all receivers that have been programmed.
Programming will not take effect if the sign: --:-- is showing on your display.
(--:-- is located between 23.59 and 00:00).
MenuSettings
SETTINGS
The following settings can be made via the SETTING menu:
HOLIDAY
INTERMEDIATE POSITION
VENTILATION/REVERSE
PROG (END LIMIT, INTERMEDIATE POSITION, VENTILATION/REVERSE)
Select language (ENGLISH GB)
ASTRO SHIFT t
Select town/city (LONDON)
LONGITUDE (Displayed in EXPERT MODE only)
LATITUDE (Displayed in EXPERT MODE only)
TIME ZONE (Displayed in EXPERT MODE only)
SUMMER/WINTER (Automatic clock adjustment for daylight saving changes)
To set a function, press the OKbutton until you come to the required menu level.
HOLIDAYSETTING
The holiday setting simulates an occupied house while you are on holiday.
If the function is activated (ON), the roller shutter/venetian blind varies randomly
from the programmed times (max.+ 30 mins.).
ENDLIMIT
The end limit is the point where the roller shutter/venetian blind is in the upper
or lower position.
INTERMEDIATEPOSITION
The intermediate position is a position of the roller shutter/venetian blind be-
tween the upper and lower limits that can be freely selected. This position can
also be reached from the upper position after programming.
Press the DOWNbutton twicein rapid succession to move to the intermediate
position.
VENTILATION/REVERSE
The ventilation/reversing position is a position of the roller shutter/venetian
blind between the upper and lower limits that can be freely selected. Using this

Table of Contents