Product Description
10 CP6700-0001-00x0/ CP6706-0001-00x0
2.4.5 Protective Earthing (PE)
The low-resistance protective earthing of the Panel PC is established via the screw connection (PE).
CAUTION
Protective Earthing (PE)
The protective conductor connection must not be used for other potentials. “PE” and
“0V” (24V system power supply) must be connected to the same potential (connected
in the control cabinet).
The wiring in the control cabinet must occur in accordance to the standard
EN 60204-1:2006 (PELV = Protective Extra Low Voltage).
EN 60204-1:2006 part 6.4.1: b): One side of the circuit or one point of the power
source must be connected to the protective earth conductor system.
CAUTION
Breaking the Power Supply/ Shutting down
Never disconnect the ground connection when switching off the device. Always
disconnect the 24V cable, other wise electricity can still flow due to the screen in
dependence of the device.
Any connected devices with its own power supply must have the same potential for
“PE” and “GND” like the Panel PC system (no potential difference).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beckhoff CP6706-0001-0050 and is the answer not in the manual?

Beckhoff CP6706-0001-0050 Specifications

General IconGeneral
USB Ports2 x USB 2.0
Power Supply24 V DC
Protection ClassIP65
Ethernet10/100 Mbps
Weight1.2 kg
Touch TechnologyResistive
Ethernet Ports1 x 10/100 Mbps
Interfaces1 x RS232
Operating Temperature0°C to +55°C

Related product manuals