Synthesizers and Samplers
CAT
VCO2 Calibration
Turn on the VCO2 SAW fader.
On your external keyboard, press the A2 key and adjust the VCO2 OFFSET trimmer (VR44 on the bottom side) while
observing the tuner display (A2-110Hz).
On your external keyboard, press the A5 key and adjust the VCO2 SCALE trimmer (VR43 on the bottom side) while
observing the tuner display (A5-880Hz).
Turn o the VCO1 SAW fader.
Repeat steps 2 and 3 above until both notes are correct in the display. This may need to be repeated several times to
get right.
On your external keyboard, press the A5 key and adjust the VCO1 SCALE trimmer (VR41 on the bottom side) while
observing the tuner display (A5-880Hz).
Figure 2