- 30 -
Error
code
Error Cause Solutions
E23
“Rod-side pressure
channel” voltage
exceed the max.
limitation.
Refer to E12 Refer to E12
E25
“Main boom bottom
angle sensor
channel” voltage
exceed the
limitation.
Refer to E15 Refer to E15
E32
Power supply defect
+UB system not
exist at the system
start
+UB system
not exist at the
system finish
+UB
connect/break fault
+UB System and
+UB Power must be
wired separately:
+UB System
connected direct with
the crane battery.
+UB Power for
switch on/off
Re-connect/break
+UB
E37
Logical
programming fault
Programming
file fault
Flash-EPROM
fault
Update effective
software of the
system
Change
controller
E38
System program
does not comply
with crane data file
The LMI system
program is different
from crane data file
Update effective
system software or
crane data file
E39
System program
does not comply
with performance
table
The LMI system
program is different
from performance
table
Update effective
system program or
performance table
E43
RAM fault
RAM or controller
fault
Change controller