Installation RSP20/25/30/35
Release
18
09/2021
63
Type A LH/LC
EEC
LH 1490 nm 1590 nm 9/125 µm 5 dB ... 24 dB 14.29 mi ...
49.71 mi
(23 km ...
80 km)
0.25 dB/km 19 ps/(nm×km)
Type B LH/LC
EEC
LH 1590 nm 1490 nm 9/125 µm 5 dB ... 24 dB 14.29 mi ...
49.71 mi
(23 km ...
80 km)
0.25 dB/km 19 ps/(nm×km)
a. MM = Multimode, SM = Singlemode, LH = Singlemode Longhaul
b. Including 3 dB system reserve when compliance with the fiber data is observed.
Product code
M-FAST-SFP-...
Mode
a
Wave length Fiber System
attenuation
Example for F/O
cable length
b
Fiber attenuation BLP/Dispersion
-MM/LC... MM 1310 nm 50/125 µm 0 dB ... 8 dB 0 mi ... 3.11 mi
(0 km ... 5 km)
1.0 dB/km 800 MHz×km
-MM/LC... MM 1310 nm 62.5/125 µm 0 dB ... 11 dB 0 mi ... 2.49 mi
(0 km ... 4 km)
1.0 dB/km 500 MHz×km
-SM/LC... SM 1310 nm 9/125 µm 0 dB ... 13 dB 0 mi ... 15.53 mi
(0 km ... 25 km)
0.4 dB/km 3.5 ps/(nm×km)
-SM+/LC... SM 1310 nm 9/125 µm 10 dB ... 29 dB 15.53 mi ...
40.39 mi (25 km ...
65 km)
0.4 dB/km 3.5 ps/(nm×km)
Table 14: Fiber port 100BASE-FX (SFP fiber optic Fast Ethernet Transceiver)
Product code
M-SFP-BIDI...
Mode
a
Wave length
TX
Wave length
RX
Fiber System
attenuation
Example for
F/O cable
length
b
Fiber
attenuation
Dispersion
Table 13: F/O port (bidirectional Gigabit Ethernet SFP transceiver)