Instructions for use and installation instructions
Figure 4: Gas regulating block; Operating Knob in ON-position
l Possible error messages:
* Long beeps (0.8 secs on, 0.2 secs off) during ignition:
Receiver batteries need changing soon (having heard this signal, the
appliance can be ignited another ten times approximately).
* 5 second unbroken tone:
Error. For example, one of the cables may not be properly connected,
the “O I” switch is not in the “I” position.
* 5 short beeps (0.2 secs on, 0.2 sec off):
Ignition of the pilot light and main burner failed. Possible cause: air in
the pilot light pipe.
Important: If the pilot flame goes out, then wait for
at least 5 minutes before repeating the
above procedure.
Setting the flame height/extinguishing the fire
l After ignition, the burner automatically sets the flames to the maximum height.
l Press the button to lower the flames or turn off the burner. (To extinguish the fire
select “STAND BY”.) (Touch the button to lower the flames gradually.)
l Press the button to raise the flames. (Touch the button to raise the flames
gradually.)
Motor-Knob
(in maximum position)
Microswitch
Operating Knob
Connection Piezo Igniter
(only for MANual control)
ON/OFF Switch
8 Wire
Receiver Jack