When fitting the appliance, it can be levelled with the adjustable feet.
Position the gas supply pipe such that it can be easily mounted after installation.
If the appliance has a operating unit, the gas pipe must lead to where the operating unit
(built in), the gas regulating block (and the receiver) assembly are fitted.
The appliance must not make contact with a flammable rear wall.
3.5.1 Connecting the gas
Important: During gas connection, take care not to twist the gas
regulating block. Make sure that both the gas regulating
block and the supply pipes are not subjected to stresses.
Appliance with operation in the separate operating unit (built in or otherwise):
• The control unit and piping are supplied separately (flat packed)
Remove the decorative edging and door of the operating unit. Fit the separate
operating unit with the gas control block and receiver max. 50 cm from the appliance.
Figure 24: Operating unit
Connect the supplied Ø8 mm copper gas pipe to the underside of the burner plate on
the fire using the compression coupling.
ATTENTION !!!
BLOW THE INSIDE OF THE COPPER PIPE WELL CLEAN
AFTER BENDING
The connections for the main burner (Ø8 mm copper), pilot light (Ø4 mm copper or
aluminium), thermocouple (thermocouple interrupter) and piezo cable can now be
made at the gas regulating block in the operating unit. If the system has remote control,
the piezo cable must be connected to the receiver (see figure 25).
Operating unit
Frame with