INSTALLATION - 90CM
STEP 1 : PREPARE INSTALLATION
Do not lift the appliance by the door
handle.
Removethexingscrewsfromthe
polythene bag on the top of the appli-
ance, but leave the appliance in the base
tray packaging until you are ready to
install it.
Whilst every care is taken to eliminate
burrs and raw edges from this appliance,
please take care when handling - we
recommend the use of protective gloves
during installation.
Please note that the weight of this appli-
ance is approximately 48kg (unpacked).
Take care when lifting it into the housing
unit - always use an appropriate method
of lifting.
Note:Whenremovingtheappliancefrom
the base tray packaging care should be
taken to ensure the appliance is not dam-
aged.
Siting the appliance
If this appliance is to be installed near to
a corner where the adjacent cabinets run
at right angles forward of the appliance,
there must be a gap of at least 90mm
between the appliance and the cabinets,
to prevent overheating of the cabinets.
When installed in a typical 600mm deep
built in housing unit, the false back
should be removed from the housing unit,
to provide the necessary depth for instal-
lation.
When the false back is removed, it is nor-
mally the case that the support shelf for
the appliance leaves a gap between the
back edge of the support shelf and the
rear wall of approximately 80mm.
If no gap occurs between the back edge
of the shelf and the wall behind the unit,
you must create a gap of at least 30mm
by shortening the shelf and any other
shelf below the appliance.
Cut 12mm from the top of any plinth that
maybetted(seediagram).
Important:Donotmodifytheouterpan-
els of this appliance in any way.