TECHNICAL DATA
Data badge
Lower part of front frame and rear of
appliance
Type of gas
This cooker must only be used on Natural
Gas or LPG only.
Gas category Natural Gas/ULPG
Pressure setting
Natural Gas @ 1.0 kPa - ULPG @2.75kPa
Appliance class
Class 3, built-in oven and grill
Countries of destination
AU&NZ
Electrical supply
240V ~ 50Hz
Max load @ 240V
60G - 1885W / 70G & 90G - 1920W
Warning: This cooker must be earthed.
Gas Burner Nominal Rate on Injector size
Nat gas Oven 9.0 MJ/h 144
Grill Electric - 1850W NA
Total heat input 9.0 MJ/h
Gas Burner Nominal Rate on Injector size
LPG Oven 8.46 MJ/h 0.82
Grill Electric - 1850W NA
Total heat input 8.46 MJ/h
Gas Burner Nominal Rate on Injector size
Nat gas Main Oven 9.0 MJ/h 144
Top Oven 6.3 MJ/h 180 Amal
Grill Electric - 1850W
Total heat input 15.3 MJ/h
Gas Burner Nominal Rate on Injector size
LPG Main Oven 8.46 MJ/h 0.82
Top Oven 6.50 MJ/h 0.72
Grill Electric - 1850W
Total heat input 14.96 MJ/h