4. Reinstall drain bolt before filling the engine with fresh oil up to the maximum
mark on the dipstick. Do not overfill oil reservoir. Use a funnel to prevent
spillage.
5. Reinstall oil dipstick and tighten.
Note
Oil capacities: BG4650E (600mL), BG6250E (700mL), BG11500E (1.1L),
BG11500DE (1.1L)
SAE 10W-30 or SAE Synthetic 5W-30 is recommended for general use.
Use of synthetic oil does not change maintenance intervals.
DO NOT OVERFILL.
Note
Do not tilt the generator when adding engine oil. This could result in
overfilling and damage to the engine.
Use high quality engine oil with strong detergents. Using non-detergent
or 2-stroke oil could shorten the engine’s working life.
Handle and store engine oil with care, avoid getting dirt or dust into the
oil.
Do not mix dierent engine oils.
Before the engine oil falls below a safe level, the low oil alert system will
automatically shut o the engine. The low oil light will turn on.
To avoid the inconvenience of unexpected engine shuto, check the
engine oil level as often as possible.
Use 4-stroke engine oil, certified to meet or exceed API standard SG, SF,
SAE ratings.
Air Filter Cover
Foam Air
Filter
Knob
0°C
10 20 30 40 50-10-20-30
20
32°F
40 60 80 100 120
°C
°F0-20
15W-50
10W-30
Synthetic 5W-30
5W-30
Effective Viscosity Range of Engine Oils
BG4650E

Table of Contents

Other manuals for Benchmark BG Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Benchmark BG Series and is the answer not in the manual?

Benchmark BG Series Specifications

General IconGeneral
BrandBenchmark
ModelBG Series
CategoryPortable Generator
LanguageEnglish

Related product manuals