EasyManua.ls Logo

Benchmark LA4 - Balanced Analog Inputs; Unbalanced Analog Inputs; Status Display; AC Power Requirements

Benchmark LA4
49 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instruction Manual for LA4 with 1.0.X Firmware REV A Page 39
Balanced Analog Inputs
Number of Unbalanced Analog Inputs
4 (2 stereo pairs)
Input Connectors
Gold-Pin Neutrik™ XLR - female
Input Impedance
>50 k Ohms
Maximum Input Level
+28 dBu, , 19.5 Vrms
Input Selection and Muting
Gold-Contact Relays
Input State when Power is Off
Inputs are Disconnected using Relays
Unbalanced Analog Inputs
Number of Unbalanced Analog Inputs
4 (2 stereo pairs)
Input Connectors
Gold RCA - female
Input Impedance
>50 k Ohms
Maximum Input Level
+12.2 dBu, 3.2 Vrms
Input Selection and Muting
Gold-Contact Relays
Input State when Power is Off
Inputs are Disconnected using Relays
AC Power Requirements
Nominal Operating Range
100 240 VAC, 50 - 60 Hz
Min/Max Operating range
90 260 VAC, 47 - 63 Hz
Power
< 0.5 Watts Standby
12 Watts Typical Program
17 Watts Maximum
Fuses (2 required)
5x20 mm, 0.5 A 250 V Slo-Blo
®
Type
Status Display
Type
3.5" Color TFT with Capacitive Touch
Volume Indication
Bar Graph and dB Gain
MUTE Indicator
On screen
-20 dB DIM Indicator
On screen
Input Name
8-Character, User Programmable
Input Connector Display
Input Number, Connector Type

Table of Contents