18
BLC
Enables or disables the block maintaining function.
Recommended for hydraulic motors to keep the leaf resting against the mechanical stop
block.
On: Block maintaining function enabled. Every 2 hours the control unit makes a closing
manoeuvre with a duration of about 3s to keep the leaf in contact.
Off: Block maintaining function disabled.
(OFF)
SPN
Enables or disables starting torque function.
On: Starting torque enabled. At the start of each manoeuvre for 2s the motor operates at
maximum torque.
Off: Starting torque disabled.
(ON)
LTCA
Selects the operating mode of the blinking light during the time TCA
On: Blinking light on during TCA
Off: Blinking light off during TCA
(OFF)
htr
Enables or disables Man present function.
On: Man Present operation.
The OPEN/CLOSE buttons must be held down during the whole manoeuvre.
Off: Automatic operation.
(OFF)
1mot
Select the 1/2 motors operating mode:
On: only one motor (motor 1) active. Function to be used in the following cases:
- for single motor, to connect M1:4-5-6.
- for two syncronized motors (for instance overhead door), to connect M1:4-5-6 and M2:7-
8-9. You need to regulate the parameters related to the motor 1, the limit switch entries
M2 are disarmed (not activate).
Off: Both motors operating.
(OFF)
not
The calculation of residual operating time is activated or deactivated in the event of partial
operations:
On: Calculation of deactivated time. In case of partial operations, the operating time is
reset. The following operation restarts for the entire time preset by parameter TM1/TM2.
Off: Calculation of activated time. In case of partial operations, the operating time is stored
in memory and then subtracted from the TM1/TM2 parameter value in the following opera-
tion.
(ON)
ENC
The Encoder is enabled or disabled. See section “ TYPES OF INSTALLATIONS”
On: Encoder enabled – The anti-crash sensor is activated.
Off: Encoder disabled – The anti-crash sensor is deactivated.
(OFF)
Cvar
Enables or disables the programmable code transmitters.
IMPORTANT: The transmitters with programmable code can only be used in conjunction
with the Rolling Code HCS transmitters.
On: Radio receiver enabled only for transmitters Rolling Code (ARC or HCS, the first
transmitter sets the operating mode).
Off: Receiver enabled for transmitters Rolling Code HCS and programmable (self-learning
and dip/switch).
(ON)
mloc
Selects the type of electric lock used.
On: Magnetic electric lock, normally fed at 12Vdc.
Before each opening manoeuvre the power supply is interrupted for the time set by the
parameter TLOC.
Off: Electric lock with latch, normally not fed.
Before each opening manoeuvre power is fed at 12Vdc for the time set by the parameter
TLOC.
(OFF)
TRK
The check for integrity of TRIAC is enabled or disabled.
On: Activated check: if TRAC is faulty, the motor does not start.
Off: the TRIAC is not checked.
(OFF)
TST1
The test of photocells to PHOT O input is enabled or disabled.
On: Test is enabled. If the test is negative, no operation is performed. See Fig.2 “PHOTO
TEST”.
Off: Test is disabled.
(OFF)
TST2
The test of photocells to PHOT C input is enabled or disabled.
On: Test is enabled. If the test is negative, no operation is performed. See Fig.2 “PHOTO
TEST”.
Off: Test is disabled.
(OFF)