17
EN
TsM1
Motor 1 slowing time
Regulates the duration of the slowing phase of motor 1 on opening and closing.Value is
calculated as a percentage on the space covered during the complete operation.
0 = slowing time disabled.
0-99-(0%)
TsM2
Motor 2 slowing time
Regulates the duration of the slowing phase of motor 2 on opening and closing. Value is
calculated as a percentage on the space covered during the complete operation.
0 = slowing time disabled.
0-99-(0%)
Pso1
The torque applied to motor 1 during braking in the opening phase is adjusted * 1-99-(70%)
PsC1
The torque applied to motor 1 during braking in the closing phase is adjusted * 1-99-(70%)
Pso2
The torque applied to motor 2 during braking in the opening phase is adjusted * 1-99-(70%)
PsC2
The torque applied to motor 2 during braking in the closing phase is adjusted * 1-99-(70%)
SeaU
The intervention threshold of the anti-crashing device (Encoder) during the phase at nor-
mal speed is adjusted.*
0:Off - 1:minimum sensitivity - 99: maximum sensitivity
0-99-(0%)
SEAR
The intervention threshold of the anti-crashing device (Encoder) during braking is ad-
justed *.
0:Off - 1:minimum sensitivity - 99: maximum sensitivity
0-99-(0%)
tinc
This parameter is enabled only for motors equipped with Encoder.
The encoder inhibition is regulated near the opening and closing mechanical stoppers.
1: minimum distance – 250: maximum distance
1-250-(250)
blcc
Adjusts the stoppage time after closure limit switch interception.
Recommended for motors for overhead doors equipped with limit switches.
Value expressed in tenths of a second.
0-50-(0)
blco
Adjusts the stoppage time after opening limit switch interception.
Recommended for motors for overhead doors equipped with limit switches.
Value expressed in tenths of a second.
0-50-(0)
** WARNING: AN INCORRECT SETTING OF THESE PARAMETERS MAY RESULT IN A DANGER.
COMPLY WITH REGULATIONS IN FORCE!
LOGIC (LOG)
MENU FUNCTION
ON-OFF-(Default)
MEMO
TCA
Enables or disables automatic closing
On: automatic closing enabled
Off: automatic closing disabled
(ON)
IbL
Enables or disables condominium function.
Off: condominium function disabled.
On: condominium function enabled. The step-by-step impulse or transmitter impulse has
no effect during the opening phase.
(OFF)
IbCA
During the TCA phase, the PP controls are enabled or disabled.
On: PP controls are disabled.
Off: PP controls are enabled.
(OFF)
SCL
Enables or disables rapid closing
On: rapid closing enabled. With the gate open or in the opening phase the intervention of
the photocell causes automatic closing after 3 s. Active only with TCA:ON.
Off: rapid closing disabled.
(OFF)
PP
Selects the operating mode of the ”Step by step button” and of the transmitter.
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
(OFF)
PRE
Enables or disables pre-blinking.
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
(OFF)
HAM
Enables or disables the inversion stroke function
On: Function enabled. Before each opening manoeuvre the control unit orders a manoeu-
vre of 2s in the opposite direction to facilitate the release of the electric lock.
Off: Function disabled.
(OFF)