20
SLD2
Adjusts motor 2 speed during slowing phases.
This value is expressed in percentage.
30-70 (50%)
SpD1
Adjusts motor 1 speed during normal speed phase.
Value expressed in percentage.
30-99 (99%)
SpD2
Adjusts motor 2 speed during normal speed phase.
Value expressed in percentage.
30-99 (99%)
Pso1
The anti-crash device (amperometric sensor) operation is adjusted in the opening
phase, at reduced speed - Motor 1.
1-99-(20%)*
Psc1
The anti-crash device (amperometric sensor) operation is adjusted in the closing
phase, at reduced speed - Motor 1.
1-99-(20%)*
Pso2
The anti-crash device (amperometric sensor) operation is adjusted in the opening
phase, at reduced speed - Motor 2.
1-99-(20%)*
Psc2
The anti-crash device (amperometric sensor) operation is adjusted in the closing
phase, at reduced speed - Motor 2.
1-99-(20%)*
SeaU
NOT USED 0-99-(0%)
SEAR
NOT USED 0-99-(0%)
tinc
NOT USED 1-250-(250)
* 1: minimum force/torque - 99: maximum force/torque.
16.2) LOGIC (LOG)
MENU FUNCTION ON-OFF-(Default) MEMO
TCA
Enables or disables automatic closing
On: automatic closing enabled
Off: automatic closing disabled
(ON)
IbL
Enables or disables condominium function.
On: condominium function enabled. The step-by-step impulse or transmitter
impulse has no effect during the opening phase.
Off: condominium function disabled.
(OFF)
ibca
The multi-flat function is enabled or disabled during the TCA counting.
On: the bloc of flat function is enabled. The Step-by-Step signal or the transmitter
signal has no effect during the TCA counting.
Off: the bloc of flat function is disabled.
(OFF)
SCL
Enables or disables rapid closing
On: rapid closure is enabled. With open gate, or in the opening phase, the
activation of the photocell causes the automatic closure 3sec after the total
opening of the gate. It is activated only with TCA:ON
Off: rapid closing disabled.
(OFF)
PP
Selects the operating mode of the ”Step by step button” and of the transmitter.
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
(OFF)
PRE
Enables or disables pre-blinking.
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
(OFF)
HAM
Enables or disables the inversion stroke function
On: Function enabled. Before each opening manoeuvre the control unit orders a
manoeuvre of 2s in the opposite direction to facilitate the release of the electric
lock.
Off: Function disabled.
(OFF)
Blco
Enables or disables the block function in opening.
On: Block function enabled. After the intervention of the opening Limit switch the
control unit delays arrest by about 0.5s, so to allow a better strike of the shutter
on the stop locks.
Off: Block function disabled
(OFF)
Blcc
Enables or disables the block function in closing.
On: Block function enabled. After the intervention of the opening Limit switch the
control unit delays arrest by about 0.5s, so to allow a better strike of the shutter
on the stop locks.
Off: Block function disabled.
(OFF)