21) ERROR MESSAGES
Some messages that are displayed in case of function anomalies are listed as follows:
Amp1
Obstacle error motor 1/anti-crushing Check presence of obstacles on motor 1 leaf run
Amp2
Obstacle error motor 2/anti-crushing Check presence of obstacles on motor 2 leaf run
Err1
Motor 1 circuit checking error Check motor 1 connections
Err2
Motor 2 circuit checking error Check motor 2 connections
Err3
error/fault power circuit Request technical assistance and eventually replace control unit.
Err4
PHOT photocell checking error Check connections, PHOT photocell alignment or presence of obstacles.
Err5
PHOTC photocell checking error Check connections, PHOTC photocell alignment or presence of obstacles.
Err6
Error edge active (during autoset) In autoset phase, the safety edge has intervened.
Err7
Error active stop (during autoset) In autoset phase, the STOP input has intervened.
Err8
Error active input (during autoset) In autoset phase a PP/Open/Close input has intervened.
thrm
Motor thermal protection intervention
Wait for motor cooling, in case reset does not take place, motor replace-
ment may be necessary
22) INSPECTION AND COMMISSIONING
The respect for the indications given below is indispensable to guarantee the maximum safety of the automation.
The BENINCÀ authorised technician must perform all tests envisioned by the Law, Standards and Regulations in force
depending on the risks present, particularly respecting all requisites of the EN 12445 Standard, which establishes the test
methods for gate automations.
INSPECTION
1 Check that the model selected is suitable for the type of application and that all automation components have been installed
correctly, with respect to the indications in this manual.
2 Test opening and closure and control that the movement of the leaf is regular without friction points.
3 Check that all electric connections are made correctly and with cables that are in compliance with the Standards.
4 Check the correct functioning of photocells, transmitters, key selectors, manual release devices (see paragraph 13 “SAFETY
DEVICES”.
5 Take the measurement of the force of impact according to that indicated by the EN 12445 Standard, intervening, if necessary on
the parameters and repeat the measurement.
COMMISSIONING
Commissioning of the automation can only be performed if all of the previously-described inspection phases have had a
positive result.
1 Apply the warning plate, supplied with the automation, to the gate in a well-visible position.
2 Apply a plate to the gate that contains the following data: Type of automation, name and address of the person in charge of com-
missioning (manufacturer), serial number, year of manufacture and CE mark.
3 Realise the technical file as per indications of the EN 12445 Standard, attaching the entire drawing, electric wiring diagrams (e.g.
figure 3), risk analysis and solutions adopted, declaration of conformity of the manufacturer of the devices used (included in this
manual).
4 Fill in and supply the owner of the automation with the declaration of conformity.
5 Realise and supply the owner with the “user guide” for the automation, also using the user guide present in this manual.
6 Realise and supply the owner of the automation with the periodical maintenance plan.
7 Do not start the automation before the owner has been informed regarding the dangers and risks that are still present.
KMB24