Adjusts the duration during the CLOSING slowing phase*. 1-99-(20%)
PM0
Adjusts the torque applied to the motor during the OPENING phase* 1-99-(30%)
PMC
Adjusts the torque applied during the CLOSING phase*. 1-99-(30%)
PSO
Adjusts the torque applied to the motor during OPENING slowing* 1-99-(30%)
PSC
Adjusts the torque applied to the motor during CLOSING slowing*. 1-99-(30%)
TSPN
Adjusts the inrush time. During the inrush time, the maximum torque is applied and the
amperometric sensor is not enabled.
Value expressed in tenths of a second
5-50-(15)
blco
Adjusts the delay time after intervention of the OPENING limit switch.
Value expressed in tenths of a second
With value 0 the function is disabled.
The function can only be enabled if the control unit detects the presence of the
OPENING limit switch.
0-30-(0)
blcc
Adjusts the delay time after intervention of the CLOSING limit switch (optional accessory).
Value expressed in tenths of a second.
With value 0 the function is disabled.
The function can only be enabled if the control unit detects the presence of the
CLOSING limit switch.
0-30-(0)
TLS
Activation time of the courtesy light, and activation time of the AUX1 contact (if the AUX1
parameter is set to 2).
1-240-(60s)
T2Ch
Sets the switching time of the second radio channel.
0:bistable output, on each activation of the second radio channel the output changes
status
from 1 to 1250: switching time in seconds
0-250-(1s)
ALRM
Alarm output enables when at least one of the following inputs remains active for the time
set (STOP - PHOTA - PHOTC - BAR - SWO+SWC).
It is necessary parameters AUX 1 is set to 7 (Alarm output)
Value expressed in seconds.
30-240 (60s)
spin
Sets the inversion space in the event of obstacle detection.
Value expressed in percentage on the entire stroke.
1- 99 - (99)
SASC
Sets a short inversion once the closure limit switch has been reached.
It may be useful to facilitate the manual unlocking of the door.
Value expressed in tenths of a second
0- 40 - (0)
TINC
Adjusts the obstacle inhibition space near the mechanical stop in opening and closure.
Inside this space, possible obstacles will be interpreted as mechanical stops.
0- 50 - (10)
sair
Sets the partial opening percentage activated by the SAIR function of the transmitter.
Value expressed in percentage on the entire manoeuvre.
1-10- (3%)
SeaU
Adjusts the intervention threshold of the anti-crushing device (encoder) during the phase
at normal speed.
0:Off -1: minimum sensitivity - 99: maximum sensitivity
0-99-(1%)
SEAR
Adjusts the intervention threshold of the anti-crushing device (encoder) during the slow-
down phase*.
0:Off -1: minimum sensitivity - 99: maximum sensitivity
0-99-(1%)
INp1
Sets the operating mode of the button P1 on the board.
0: OFF (no function)
1: PP (same functionality of Step-Step input)
2: Enables the courtesy light
0-2-(1)
In 1
Sets the IN1 input operating mode
2: OPEN function, connect N.O. button
3: CLOSE function, connect N.O. button
4: Input function for active photocells in OPENING and CLOSING (PHOTA), connect the
N.C. contact of the photocell.
5: Input function for active photocells in CLOSING (PHOTC), connect the N.C. contact of
the photocell.
6: CLOSING limit switch input of motor 2
7: OPENING limit switch input of motor 2
2-7-(2)
In 2
Same setting as input IN1 but referring to input IN2 2-7-(3)