13) DIAGNOSTICS
In the event of malfunctions, by pressing key + or - the status of all inputs (limit switches, control and
safety) can be displayed. One segment of the display is linked to each input. In the event of failure it
switches on according to the following scheme.
PHOT 0
SWC
STOP
SWO
PHOT C
DAS
P.P. PED OPEN CLOSE
14) FUSES
F1 Protection fuse of transformer
F2 Output protection fuse of accessories and signals
F3 Output protection fuse for motor and blinker
15) ERROR MESSAGES
Some messages that are displayed in the event of malfunctions are shown hereunder:
Err1
Motor Technical assistance is required.
Err4
Error, PHOT O circuit check Check connections, alignment of PHOT O photocell or obstacle present.
Err5
Error, PHOT C circuit check Check connections, alignment of PHOT C photocell or obstacle present.
ENC
Error, encoder Error to connection or faulty encoder.
Amp
Obstacle detection An obstacle present is indicated (anti-crash device).
16) WARNING
The RC product insurance policy, which covers any injuries or damages to objects caused by manufacturing defects, requires the use of Benincà’s
original accessories.