Caution
It is imperative that the flue should be
properly sealed where it passes through the
roof, this can best be achieved by using the
approved method of roof flashing plate and
cravat. The flue spigot outlet on all Variante
heaters is in horizontal configuration.
Note
It should be noted that claims made under
warranty and attributed to the ingress of
water may not be considered especially if an
approved method of sealing has not been
used, or if the design of the flue has not
made provision for possible condensation
problems.
It is also recommended that BS5854: 1980
and BS5440: parts 1 and 2 are used as a
consultative document when considering flue
requirements.
If terminating through a wall only use Benson
approved horizontal terminals
2.6 Electrical Installation
All electrical
wiring and
connections
must be in
accordance with
the relevant
European,
National, and
Local
regulations as
well as to IEE
Standards.
Ensure that the Electric and Gas supplies are
turned off before any electrical work is
carried out on the heater.
Also ensure that
wiring cannot
make contact
with any metal
surfaces liable
to be subject to
high
temperatures,
and where
insulation of the
wiring could be
impaired as a
result of such
contact.
All Variante models must be earthed.
Warning