OPERATION
Do not throw items into the storage area. Failure to heed these recommendations could
result in damage to the interior of the cabinet.
Refrigerated cycle
Refrigerators: During the refrigeration cycle, the evaporator fans wilt run continuously even when one or
more doors are open. The lamp switch will activate the lights when opened.
1.
Every 6 hours, the unit will turn off and to allow the evaporator coil to defrost. The controller now
displays defrost symbol. When the coil temperature reaches 53°F or after 30 minutes of defrost, the unit
will turn on again.
2.
Anti-condensation heaters on door frames work in conjunction with the compressor.
3.
The factory setting for the temperature range is 34°F to 38° F.
On/Off Switch:
An on/off switch is located on the front of the bottom panel. When the unit is on, the switch will glow green.
SOLID-STATE THERMOSTAT DESCRIPTIONS
1. FRONT PANEL COMMANDS
To display target set point; in programming mode it selects a parameter or confirm an operation.
To start a manual defrost
In programming mode it browses the parameter codes or increases the displayed value
In programming mode it browses the parameter codes or decreases the displayed value
KEYS COMBINATION
To lock or unlock the keyboard
To enter in programming mode