10
Hook Timing and Position Continued
Set your machine to far right needle position. From the
lowest position bring the needle up until the hook and needle
meet. The tip of the hook should be just above the eye of the
needle.
In most cases the hook timing on your machine should be fine. If
not adjust the timing.
Locate and loosen the two stroke eccentric screws. Be very
careful not to loosen them too much and do not let the eccentric
drop down. Move the hook to the position shown. Tighten the
screws and recheck the timing.