BT-532C User manual
User input data in AI don't need to use "(" ")" instructions, coding system
automatically inserts,or will got something wrong. such as: GS 74 k 18
"019501234567890 *", 01 is the AI, the following is wrong: GS 74 18 k "(01)
9501234567890 *".
When using connection structure, the middle need to insert FNC1 (C1H Decimal =
193). input example is as follows:
GS 74 18 k "019501234567890 * 193" 029501234567890 * ""
When setting (HRI) print, control characters will replace with a space, and remove
FNC1 ~ FNC4.
1b 40 1d 48 02
1d 6b 41 0c 31 32 33 34 35 36 37 38 39 30 31 32
1d 6b 42 0c 30 32 33 34 35 36 30 30 30 30 38 39
1d 6b 43 0c 30 32 33 34 35 36 30 30 30 30 38 39
1d 6b 44 08 30 32 33 34 35 36 30 30
1d 6b 45 08 30 32 33 34 35 36 30 30
1d 6b 46 08 30 32 33 34 35 36 30 30
1d 6b 47 08 41 32 33 34 35 36 30 41
1d 6b 48 08 41 30 32 33 34 35 36 41
1d 6b 49 08 41 30 32 33 34 35 36 41
⑥
Two-dimension Bar Code Command
Setting mode type of QR code
Setting mode type of QR code
ASCII :GS ( k pL pH cn fn n
Decimal :29 40 107 pL pH cn fn n
Hexadecimal :1D 28 6b pL pH cn fn n
Setting mode type of QR code
pL=3, pH=0
cn=49
fn=67
0 ≤ n ≤ 16