ATOM 2022
BH
19
ERROR CODES
Errors will be shown on the display. In some cases, the steps required to try and resolve the error will be included
inthe error notification message. The table below shows the possible errors and how they can be resolved.
06 PEDAL ASSISTANCE SYSTEM OPERATION
ERROR DESCRIPTIONS
1 Remote abnormal signal.
RESTART THE SYSTEM.
2 Remote communication.
MAKE SURE THAT THE DISPLAY CONNECTOR 15 IS PLUGGED IN CORRECTLY.
3 Torque sensor.
RESTART THE SYSTEM.
4 Battery undervoltage.
FULLY CHARGE THE BATTERY WITH THE ORIGINAL CHARGER.
RESTART THE SYSTEM.
5 Battery undervoltage.
RESTART THE SYSTEM.
6 Motor Hall sensor.
RESTART THE SYSTEM.
7 Motor overheating.
STOP RIDING AND WAIT UNTIL THE MOTOR COOLS DOWN.
8
Drive unit sensor
overtemperature.
RESTART THE SYSTEM.
9
Drive unit current out
ofrange.
RESTART THE SYSTEM.
11 Communication.
MAKE SURE THAT THE DISPLAY CONNECTOR IS PLUGGED IN CORRECTLY.
RESTART THE SYSTEM.
Description Action required
Code
ERROR DESCRIPTIONS
12 Battery discharged.
FULLY CHARGE THE BATTERY WITH THE ORIGINAL CHARGER.
RESTART THE SYSTEM.
14 Drive unit overcurrent.
REDUCE THE LOAD ON THE MOTOR BY PEDALLING LESS OR BY REDUCING THE ASSISTANCE LEVEL.
RESTART THE SYSTEM.
24 Drive unit power.
RESTART THE SYSTEM.
25
Drive unit serial number not
detected
RESTART THE SYSTEM.
26 Drive unit reset cause.
RESTART THE SYSTEM.
33 Speed sensor.
CHECK SPEED SENSOR AND MAGNET POSITION IN THE WHEEL.
34 Drive unit overvoltage.
RESTART THE SYSTEM.
35 Cadence sensor.
RESTART THE SYSTEM.
36 Lights low voltage.
CHECK LIGHT CABLES AND POTENTIAL SHORT.
193 Cell over voltage.
FULLY DISCHARGE THE BATTERY.
FULLY CHARGE THE BATTERY WITH THE ORIGINAL CHARGER.
ONCE FULLY CHARGED, KEEP THE CHARGER PLUGGED IN FOR 2 HOURS TO BALANCE THE CELLS.
RESTART THE SYSTEM.
194 Cell undervoltage.
FULLY DISCHARGE THE BATTERY.
FULLY CHARGE THE BATTERY WITH THE ORIGINAL CHARGER.
ONCE FULLY CHARGED, KEEP THE CHARGER PLUGGED IN FOR 2 HOURS TO BALANCE THE CELLS.
RESTART THE SYSTEM.
197 Overcurrent charge.
CHECK THE STATUS OF THE ORIGINAL CHARGER.
RESTART THE SYSTEM.
198 Overcurrent discharge.
RESTART THE SYSTEM.
199 Short circuit.
CHECK CHARGER CABLE STATUS.
RESTART THE SYSTEM.
204 Temperature charging.
STOP CHARGING FOR 30 MINUTES.
RESTART THE SYSTEM.
205 Temperature discharging.
RESTART THE SYSTEM.
Description Action required
Code