Installation Checklist
Did a structural engineer approve the mounting structure? (See p. 6 for Big Ass Fans approved
mounting structures.)
Are you familiar with the function and use of the safety cables? (See pp. 14–15 for information on
properly securing the safety cables.)
:LOOWKHIDQEHLQVWDOOHGVRWKDWWKHEODGHVDUHDWOHDVWIWPDERYHWKHÀRRU"
Will the fan be installed so that the blades have at least 2 ft (0.61 m) of clearance from
obstructions?
Will the fan be installed so that it is not subjected to high winds, such as from an HVAC system?
,QVWDOOWKHIDQVRWKDWLWLV[IDQGLDPHWHUDZD\IURPDGLIIXVHULIWKHIDQLVDWVDPHOHYHORUDERYH
GLIIXVHU,IWKHIDQLVEHORZDGLIIXVHULQVWDOOWKHIDQVRWKDWLWLV[IDQGLDPHWHUIURPWKHGLIIXVHU
Will the distance between multiple fans be at least 2.5x the fans’ diameter when measured from
the centers of the fans?
If installing to an I-beam, is the upper yoke the correct size? (See p. 7 for more information on
installing the fan to an I-beam.)
If you ordered multiple fans, did you keep the parts for each fan together?
Customer Service: 1-877-BIG-FANS