* 2016-04-07
1. Check table mounting
a. Angled ==> Z-Min sensor bottom edge = 10m
b. Straight==> Z-Min sensor bottom edge = 65mm
2. Home Z
3. Start PRO-Modeby pressing „Down“ for 3 Seconds
4. Look for option „SenS2 and confirm by pressing „Teach
5. Change to the Komparativ-Mode (N2) with „up“ and „down“ andconfirm by
pressing „Teach
6. Drive the printer to the absolute position (6.5mm)
7. Screw the table up/down until the sensor shows „+4900“ on the posi-
tionsx100y100 - x100y980 - x1000y100 - x1000y980
8. Lock nuts of the table and check again
9. Drive the printer to the absolute position (6.5mm)
10. Press „Teach“ at positionx100y100
11. Drive printer to 9.9mm/9.8mm at the actual position
a. If error 41 go 0.1 down
12. Press „Teach“ ==> „GooD“ should be displayed
13. Request position with „M114“
14. Get the shown Z Value for the config (leveling-strategy.three-point-leveling.
probe_osets-150,-70,Z-Value)(should be around 16.5)
15. Activate HOLD-Mode
16. Turn both Extruder Heads to the top position with help of the adjusting
screws (x100y100)
17. Calibrate Extruder
a. iffeeler gauge 0.5mm drive to absolute Z-Position 0.5mm
18. Perform Firstlayer_adhession test (Starting high= 0.2mm),Use vernier
caliper!
a. If Extruder is to close the Z-probe Value needs to be decreased