77-2946
page 4
Technical file lodged with;
TRaC Compliance Ltd (Notified Body 0891) Moss View
Nipe Lane Up Holland WN8 9PY, UK
HAZARD CAUSE SAFEGUARDS
EXPLOSION STATIC ELECTRICITY
Use of this equipment in a
potentially explosive
atmosphere.
Vapours from flammable
liquids can catch fire or
explode from static
electricity discharges.
1. If installing this equipment in a potentially explosive
atmosphere, check the ATEX equipment category and
temperature ratings meet the requirements for the zoned area.
2. Check electrical continuity of the air supply to earth — should be
no greater than 10
6
Ω.
3. Electrically bond all metallic equipment to earth. Should be no
greater than 1 Ω.
SPECIAL CONDITIONS
FOR SAFE USE
Over pressurization of
equipment can cause
equipment failure or
injury.
Use lubricating medium
resistant to carburisation.
Improper operation or
maintenance may create
a hazard.
1. Do not exceed the stated maximum working pressures and
motor speed as specified in this manual.
2. Only a suitably approved static dissipating or conductive air
supply hoses shall be attached to the equipment and terminated
to the air supply.
3. Air supplies (compressors, etc.) shall be sited in a no hazardous
area with a filter on the air intake system to prevent the ingress
of dust or similar foreign material into the parts where
compression takes place.
4. Use lubricating medium resistant to carburisation and has an
auto ignition temperature of more than 185°C for T4 equipment.
5. User shall ensure all metallic parts of the equipment are suitably
bonded to earth. Should be no greater than 1 Ω.
We: ITW Finishing UK, Ringwood Rd., Bournemouth, Dorset, BH11 9LH, UK
As the manufacturer of the items listed below:
Piston Pumps MX432
Declare, under our sole responsibility, that, the equipment to which this document relates is in conformity with the fol-lowing
standards or other normative documents:
EN 13463-1:2009, EN 13463-5:2005, EN 982:1996 + A1:2008, EN 983:1996 + A1:2008 and EN 12621:2006
And thereby conform to the protection requirements of Council Directive 98/37/EC relating to Machinery Safety Directive and
council Directive 94/9/EC relating to Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres;
CE Ex 2 II Gc T4
Issued on: 1st Oct 2010 Authorized by:
General Manager