EasyManua.ls Logo

Biohit mLINE m3 - User Manual

Biohit mLINE m3
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Looking for more information?
Visit
us
on the
web
at http://www.artisan-scientific.com for more information:
Price
Quotations
Drivers·
Technical
Specifications.
Manuals and Documentation
Artisan
Scientific
is
You~
Source
for:
Quality
New
and
Certified-Used/Pre:-awned ECJuiflment
Tens
of
Thousands
of
In-Stock
Items
Hundreds
of
Manufacturers
Supported
Fast
Shipping and
DelIve1y
Leasing
/ Monthly
Rentals
Equipment Demos
Consignment
Service Center Repairs
Experienced Engineers and Technicians
on
staff
in
our
State-of-the-art Full-Service In-House Service Center Facility
InstraView Remote Inspection
Remotely inspect equipment before purchasing with
our
Innovative InstraView-website at http://www.instraview.com
We
bUy
used
equipment!
We
also
offer
credit
for
Buy-Backs
and
Trade-Ins
Sell
your
excess.
underutilized. and idle used equipment. Contact one
of
our
Customer
Service
Representatives todayl
Talk to a live person: 88EM38-S0URCE fB88-887-68721 I Contact
us
by
email: sales@artisan-scientific.com I Visit our website: http://www.artisan-scientific.com

Questions and Answers

  • D
    David AndersonAug 16, 2025
    Why is my Biohit Laboratory Equipment pipette leaking or dispensing too small a volume?
    • T
      Tiffany EdwardsAug 16, 2025
      Several factors can cause leakage or insufficient volume: * A newly attached tip might have non-uniform wetting of the plastic, so attach a new tip. * The tip might not be firmly attached; ensure it is properly secured. * The tip might be unsuitable; use original tips. * Foreign particles might be present between the tip and tip cone; clean the tip cone and attach a new tip. * The tip cone holder might not be tightened correctly; tighten it. * The pipette might be damaged; in this case, return it to your Biohit service representative for servicing.
  • T
    Timothy BarrettAug 19, 2025
    How to troubleshoot Biohit mLINE m3 Laboratory Equipment pipette that is out of established specifications?
    • N
      Nathan WilsonAug 19, 2025
      If your pipette is out of established specifications, consider the following: * Ensure you are following the operating instructions correctly. * Verify that you are using original tips. * Recalibrate the pipette, as the calibration may have been altered.
  • C
    Christopher OconnorAug 22, 2025
    How to fix operating button if it jammed or moves erratically in Biohit mLINE m3 Laboratory Equipment?
    • S
      Scott HammondAug 22, 2025
      If the operating button on your Biohit Laboratory Equipment is jammed or moving erratically: * Clean and grease the piston/seal and the tip cone if liquid has penetrated and dried. * Change the filter if the Safe Cone filter has been contaminated. * Apply more grease to the piston and seal if there is an insufficient amount.
  • S
    sarahhammondAug 25, 2025
    What to do if tip ejector jammed or moves erratically in Biohit mLINE m3 Laboratory Equipment?
    • L
      lesterjasonAug 26, 2025
      If the tip ejector on your Biohit Laboratory Equipment is jammed or moving erratically, remove and clean the ejector collar and tip cone, as the tip ejector collar may have been contaminated.
  • A
    Amanda RangelAug 28, 2025
    What to do if the operating button of Biohit mLINE m3 moves erratically?
    • L
      lgonzalezAug 28, 2025
      Erratic movement of the operating button can occur for several reasons: * Liquid may have penetrated the tip cone and dried; clean and grease the jammed piston/seal and the tip cone. * The Safe Cone filter may be contaminated; change the filter. * There might be an insufficient amount of grease on the piston and seal; grease accordingly.
  • M
    Mary SmithAug 31, 2025
    What to do if tip ejector jammed in Biohit mLINE m3?
    • K
      Krista SmithAug 31, 2025
      If the tip ejector is jammed, it might be due to contamination of the tip ejector collar. Remove and clean the ejector collar and tip cone.
  • J
    Jasmine PerezSep 3, 2025
    How to avoid droplets inside the tip of Biohit Laboratory Equipment?
    • C
      Christopher ConnerSep 3, 2025
      To avoid droplets remaining inside the tip, use original tips.
  • A
    Amy CollinsSep 6, 2025
    What to do if Biohit mLINE m3 Laboratory Equipment is leaking or pipetted volume is too small?
    • R
      Richard JonesSep 6, 2025
      If you're experiencing leakage or the pipetted volume is too small with your Biohit Laboratory Equipment, here's what you can do: * Ensure the tip is firmly attached, as it may be incorrectly attached. * Attach a new tip, as there may be non-uniform wetting of the plastic. * Use original tips, as the tip might be unsuitable. * Clean the tip cone and attach a new tip to remove any foreign particles between the tip and tip cone. * Tighten the tip cone holder if it is incorrectly tightened. * If the issue persists, the pipettor may be damaged. Return it to your Biohit service representative for servicing.
  • R
    Randy SmithSep 9, 2025
    Why is my Biohit mLINE m3 Laboratory Equipment out of established specifications?
    • R
      Richard Thomas MDSep 9, 2025
      If your Biohit Laboratory Equipment is out of established specifications, consider the following: * Ensure you are following the instructions for correct operation. * Use original tips, as unsuitable tips can cause this issue. * Recalibrate the pipettor, as the calibration may have been altered.
  • J
    Jillian NguyenSep 12, 2025
    How to prevent droplets left inside the tip of Biohit Laboratory Equipment?
    • J
      jessicaprestonSep 12, 2025
      If you notice droplets left inside the tip of your Biohit Laboratory Equipment, use original tips.