6
BRIEF OPERATING SEQUENCE
Turn the Main Disconnect Switch (Red Handle) “ON.”
Close Blade Door, Clutch Door, and Chamber Covers.
Twist and Pull out the Emergency Stop Switch.
Open the Loading Chamber Cover Slightly, and close again. The Slicer is now operational.
Load the product to be cut and engage the product to the Product Pusher Gripper. Close the Loading Chamber
Cover. Turn the Selector Switch to “RUN”. Press the Green Start Button.
After cutting is complete, open the Loading Chamber Cover, and while squeezing the hand lever of the Product
Pusher Assembly move it to the right to the desired location.
Open the Receiving Chamber Cover and remove the cut product.
Close the Receiving Chamber Cover.
Clean the Product Gripper of any surplus.
Repeat the previous steps.
INTERLOCK SYSTEM
The Horizontal Slicer can only Start after the Blade Door, Clutch Door and Chamber Covers are closed, and
the Emergency Stop is in the “out” position. Open one Cover briey, and close again to initiate the electronics.
The Horizontal Slicer will not operate with any of the doors and/or Chamber Covers in the open position.