SB-170-10
Halbhermetische Kompaktschraubenverdichter
Originalbetriebsanleitung
Deutsch .................................................................................................................................................... 2
Semi-hermetic compact screw compressors
Translation of the original Operating Instructions
English...................................................................................................................................................... 41
Compresseurs à vis compacts hermétiques accessibles
Traduction des instructions de service d'origine
Français.................................................................................................................................................... 80
CSH6553..CSH6593
CSH7553 .. CSH7593
CSH8553 .. CSH8593
CSH9553 .. CSH95113
CSH10563 .. CSH10573
CSH7673 .. CSH7693
CSH8673 .. CSH8693
CSH9663 .. CSH96113
CSK6153 .. CSK6163
CSK7153 .. CSK7193
CSW6583 .. CSW6593
CSW7573 .. CSW7593
CSW8573 .. CSW8593
CSW9563 .. CSW95113
CSW10563 .. CSW10593
Dokument für Monteure
Document for installers
Document pour des monteurs

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Bitzer CSH8573-140Y and is the answer not in the manual?

Bitzer CSH8573-140Y Specifications

General IconGeneral
BrandBitzer
ModelCSH8573-140Y
CategoryAir Compressor
LanguageEnglish

Summary

Safety

Authorized staff

Work on compressors must be done by qualified personnel corresponding to local regulations and guidelines.

Residual risks

Identifies unavoidable residual risks and requires careful reading of operating instructions.

Safety references

Instructions intended to prevent hazards. Safety references must be stringently observed!

Electrical connection

Safety switching devices for limiting pressure

Devices required for limiting the application range and avoiding impermissible operating conditions.

Compressor protection devices

Overview of integrated protection devices for monitoring motor and oil temperature, and rotation direction.

Monitoring of the oil circuit

Information on monitoring oil temperature and level using opto-electronic proximity sensors.

Application ranges

Use of flammable refrigerants of the A2 L safety group

Information on the use of A2L safety group refrigerants, including system requirements and operation.

Compressor and refrigeration system requirements

Specifications based on standards like EN378; recommends risk assessment cooperation with a notified body.

Commissioning

Checking pressure strength

Procedure to check the refrigerant circuit for strength pressure, preferably using dried nitrogen.

Checking tightness

Procedure to check the refrigerant circuit for tightness, preferably using dried nitrogen.

Evacuation

Steps for evacuating the system using a vacuum pump to achieve a standing vacuum below 1.5 mbar.

Charging refrigerant

Instructions for charging the system with permitted refrigerants, avoiding overcharging.

Compressor start

Detailed steps for starting the compressor, including rotation direction, oil monitoring, and setting switches.

Mounting

Operation

Maintenance

Mind when mounting or replacing

Related product manuals