SB-170-10
Halbhermetische Kompaktschraubenverdichter
Originalbetriebsanleitung
Deutsch .................................................................................................................................................... 2
Semi-hermetic compact screw compressors
Translation of the original Operating Instructions
English...................................................................................................................................................... 41
Compresseurs à vis compacts hermétiques accessibles
Traduction des instructions de service d'origine
Français.................................................................................................................................................... 80
CSH6553..CSH6593
CSH7553 .. CSH7593
CSH8553 .. CSH8593
CSH9553 .. CSH95113
CSH10563 .. CSH10573
CSH7673 .. CSH7693
CSH8673 .. CSH8693
CSH9663 .. CSH96113
CSK6153 .. CSK6163
CSK7153 .. CSK7193
CSW6583 .. CSW6593
CSW7573 .. CSW7593
CSW8573 .. CSW8593
CSW9563 .. CSW95113
CSW10563 .. CSW10593
Dokument für Monteure
Document for installers
Document pour des monteurs

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Bitzer CSH8573-140 and is the answer not in the manual?

Bitzer CSH8573-140 Specifications

General IconGeneral
BrandBitzer
ModelCSH8573-140
CategoryAir Compressor
LanguageEnglish

Summary

Safety

Authorized staff

Specifies requirements for qualified and authorized personnel performing work.

Residual risks

Highlights potential hazards that may remain after safety measures are implemented.

Safety references

Explains the meaning of safety symbols and references used throughout the manual.

General safety references

Provides fundamental safety guidelines and references for overall safe operation.

Application ranges

General operation requirements

General safety and operational rules for systems with flammable refrigerants.

Commissioning

Compressor start

Detailed steps for starting the compressor, including initial operational checks.

Checking the rotation direction

Crucial procedure to ensure the compressor rotates in the correct direction.

Lubricationoil level monitoring

Monitoring oil circulation and level during and immediately after compressor start.

Set high pressure and low pressure switches (HP + LP)

Adjusting cut-in and cut-out pressure setpoints for safety pressure switches.

Checking the operating data

Monitoring key operating parameters like temperatures, pressures, and currents.

Particular notes on safe compressor and system operation

Specific advice for preventing common failure modes and ensuring safe operation.

Mounting

Connecting the pipelines

Instructions for correctly connecting refrigerant and oil lines to the compressor.

Electrical connection

Checklist

A comprehensive checklist for all steps involved in the electrical connection process.

Safety switching devices for limiting the pressure (high pressure switch and low pressure switch)

Function, requirements, and setting of safety devices for pressure limit monitoring.

Compressor protection devices

Overview of integrated protection devices that monitor compressor operating conditions.

Temperature control circuit

Description of the circuit monitoring motor and oil temperature sensors.

Monitoring of rotation direction, phase sequence and phase failure

Functions for monitoring rotation direction, phase sequence, and electrical phase failures.

SE-E1

Details on the standard SE-E1 compressor protection device and its monitoring functions.

CM-SW-01

Information on the CM-SW-01 module integrating multiple compressor monitoring functions.

SE-i1

Details on the SE-i1 protection device, suitable for FI and soft starter applications.

SE-E3

Information on the SE-E3 protection device for high voltage motor applications.

Monitoring of the oil circuit

Methods and devices for monitoring the compressor's oil level and temperature.

Operation

Maintenance

Mind when mounting or replacing

Related product manuals