EasyManuals Logo

BK Precision 1901B Programming Manual

BK Precision 1901B
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
12
Command code &
Return value
Function
Example
Input command:
GETD[CR]
Return value:
[voltage][current][stat
us][CR]
OK[CR]
Get display voltage,
current, and status
reading from power
supply
Input command:
GETD[CR]
Return value:
030201450
OK
Indicates voltage reading is 3.02
V and current reading is 1.45 A.
Power supply is in CV mode
Input command:
GETM[CR]
Return value:
[preset 1 voltage]
[preset 1 current][CR]
[preset 2
voltage][preset 2
current][CR]
[preset 3
voltage][preset 3
current][CR]
OK[CR]
Get preset memory
values
Input command:
GETM[CR]
Return value:
015015
025025
035035
OK
Indicates preset 1 voltage and
current is 1.5 V and 1.5 A, preset
2 voltage and current is 2.5 V
and 2.5 A, preset 3 voltage and
current is 3.5 V and 3.5 A
Input command:
RUNM{<memory>}[CR
]
Return value:
OK[CR]
Set voltage and
current using values
saved in preset
memory locations
Input command:
RUNM0[CR]
Return value:
OK[CR]
Sets voltage and current using
values from memory location 1
Input command:
SOUT{<output>}[CR]
Return value:
OK[CR]
Output On/Off control
Input command:
SOUT1[CR]
Return value:
OK[CR]
Switches output OFF
Input command:
SOVP{<voltage>}[CR]
Return value:
OK[CR]
Set upper voltage limit
of power supply
Input command:
SOVP151[CR]
Return value:
OK[CR]
Sets upper voltage limit to 15.1 V

Other manuals for BK Precision 1901B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BK Precision 1901B and is the answer not in the manual?

BK Precision 1901B Specifications

General IconGeneral
BrandBK Precision
Model1901B
CategoryPower Supply
LanguageEnglish