13
Command code &
Return value
Function
Example
Input command:
SOCP{<current>}[CR]
Return value:
OK[CR]
Set upper current limit
of power supply
Input command:
SOCP108[CR]
Return value:
OK[CR]
Sets upper current limit to 10.8
A
Input command:
GOVP[CR]
Return value:
[voltage][CR]
OK[CR]
Get upper voltage
limit of power supply
Input command:
GOVP[CR]
Return value:
152
OK
Indicates upper voltage limit is
set to 15.2 V
Input command:
GOCP[CR]
Return value:
[current][CR]
OK[CR]
Get upper current
limit of power supply
Input command:
GOCP[CR]
Return value:
052
OK
Indicates maximum current limit
is set to 5.2 A
Input command:
GMAX[CR]
Return value:
[voltage][current][CR]
OK[CR]
Get power supply
maximum voltage and
current values
Input command:
GMAX[CR]
Return value:
180200[CR]
OK[CR]
Indicates maximum voltage is
18.0 V and maximum current is
20.0 A