9
ENGLISH
(Original instructions)
POWERCOMMAND feature
The POWERCOMMAND feature (3) is located on the
GWC1820PC tool handle as shown in Figure G. It allows you
to optimise the tools performance and boost the power as
needed.
u Switch the blower on.
u To activate the “Boost” mode, press and hold the
POWERCOMMAND button down.
u To deactivate the “Boost” mode, release the
POWERCOMMAND button.
u Operate in “Normal” mode for most sweeping needs.
(Longer runtime will be achieved.)
u Activate “Boost” mode as needed to clear heavy or wet
debris.
Troubleshooting
Problem Possible cause Possible solution
Unit will not start. Battery not installed
properly.
Check battery
installation.
Battery not charged. Check battery
charging requirements.
Battery will not charge. Battery not inserted into
charger.
Insert battery into
charger until green
LED appears.
Charger not plugged in. Plug charger into a
working outlet. Refer
to “Important Charging
Notes” for more details.
Check current at
receptacle by plugging
in a lamp or other
appliance.
Check to see if
receptacle is
connected to a light
switch which turns
power off when you
turn out the lights.
Surrounding air
temperature too hot or
too cold.
Move charger and
tool to a surrounding
air temperature of
above 40 degree F
(4.5°C) or below 105
degree F (+40.5°C).
Protecting the environment
Z
Separate collection. Products and batteries
marked with this symbol must not be disposed of
with normal household waste.
Products and batteries contain materials that can be
recovered or recycled reducing the demand for raw materials.
Please recycle electrical products and batteries according to
local provisions.
Technical data
GWC1815
Input Voltage
V
DC
18
No-Load Speed
/min
12500
Weight
kg
1.7
Battery BL1518
Voltage
V
DC
18
Capacity
Ah 1.5
Type
Li-Ion
Charger
400mA
GWC1820PC
Input Voltage
V
DC
18
No-Load Speed
/min
10,000 - 12,500
Weight
kg
1.7
Battery BL2018
Voltage
V
DC
18
Capacity
Ah 2
Type
Li-Ion
Charger
400mA
Hand/arm weighted vibration value according to
EN 50636-2-100:
= < 2,5 m/s
2
, uncertainty (K) = 1,5 m/s
2
.
L
PA
(sound pressure) 72 dB(A)
uncertainty (K) = 2,8
dB(A)
EC declaration of conformity
MACHINERY DIRECTIVE
OUTDOOR NOISE DIRECTIVE
%
GWC1815/GWC1820PC blower
Black & Decker declares that these products described under
"technical data" are in compliance with:
2006/42/EC, EN 60335-1: 2012+A11;
EN 50636-2-100:2014
2000/14/EC, Blower, Annex VI
DEKRA Certication B.V., Utrechtseweg 310,
6802 ED Arnhem, The Netherlands
Notied Body ID No.: 0344