EasyManua.ls Logo

Black Hawk FS Future - Common Problems and Solutions

Black Hawk FS Future
34 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
The most common problem is that the battery is low or in need of a charge. In every case, please ensure
that the battery is fully charged.
Questions Answers
Why do I have to constantly change the delay?
Changing the delay usually occurs after a
strong signal is received or you accidentally
change the setting.
There could be an area with higher
mineralization causing the delay to be reset.
When the unit was balanced to the ground, it
was either too low or too high above the
ground.
Why is it so hard to balance the unit?
The coil is directly on the ground as you are
setting the delay and threshold.
You may be too close to an electrical appliance
or motor.
Be sure your area where you are balancing the
unit is clean.
Why does it beep and there is no target?
Your coil is too close to the ground and it is
receiving feedback.
There is a target, then it goes away, why?
Check your ground balance, most likely you
adjusted it in the field and have reset the unit
and balanced it out.
The size of the item may be extremely small or
it may lie just within the range of the detector.
I hear a target, then I can't find it again, why?
The coil may be touching or just about to touch
the ground and give a signal that there is an
anomaly.
I don't see anything in the display
Adjust the brightness of the monitor. If in direct
sunlight put hand over display to shade it.
I don't hear any tones
Check to make sure that the volume is loud
enough and that there is a coil attached. If
there is no coil then the unit will remain silent.
Check the coil to ensure that there are no tears
in cable.
You need to ground balance the unit again,
perhaps an adjustment knob was accidentally
turned.
Orient Detectors
www.orientdetectors.com