CF 300 Flight Manual sect. 3 Emergency Procedures
BY BLACKSHAPE
Document n°
BPU/FM003 Rev 3 dtd 03/06/2014 Page 34
-66
3.3.9 Electrical Failure
a) Total Electrical Power Failure
(1) BATT Circuit Breaker If Tripped, Reset
(2) GEN/BATT CHECK ON
(3) If No Improvem ent Land as soon as Possible
b) Generator Failure
(1) GEN Annunciator Illum inated / Indication on Avionic
System (Dynon)
(2) GEN/BATT RESET OFF/ON
(3) GEN Circuit Breaker If Tripped, Reset
(4) If Unsuccessful:
A. Switch OFF all non-flight essential electrical
consumers
B. Monitor Voltmeter/Ammeter
C. Land as soon as Possible
NOTE
On shutdown of generato r , there is up to 30 min of battery power if it is
fully charged and properly maintained.
c) Electric Charge
(1) AMP/VOLT CHECK
(2) GEN OFF
(3) VOLT Green Arc
(4) GEN ON
(5) VOLT CHECK
IF NO IMPROVEMENT:
(6) GEN OFF
3.3.10 Flaps System Failure
(1) Flaps Mode MAN
(2) Flaps Actuator Check Operation/Position
IF NO IMPROVEMENT:
(3) Flaps Circuit Breaker RESET
(4) Actuator CHECK Operation
(5) In Case of Failure Landing Procedure with No
Flaps