EBE 350 E Operating Instructions
Fault diagnosis
Fault Possible cause Remedy
Control
system
switches off
during
operation
Connection cable is
defective.
Cables connecting the
units (travel motor, etc.)
are defective.
Motor protection switch
has triggered.
Main switch of the filter
unit switches off due to
overload.
Replace the cable.
Replace the cable.
Have the fault checked
by an electrician.
Switch the main switch
“ON“ - with fault, have
the unit checked by an
electrician.
Machine does
not travel
Fuse defective or short
circuit in the travel motor
lead or tachometer lead,
motor defective.
Control unit defective.
Potentiometer defective.
Have the unit checked by
an electrician.
Replace the control unit.
Replace the
potentiometer.
Note: If the motor protection switch of the blast wheel motor has
been triggered by overload, it can be switched on again after a short
cooling down period.
5