Blaze Grills by Blaze Outdoor Products Instructional Book
11
Turn on the gas
On Natural Gas systems, turn the main feed valve to the grill.
On LP systems, turn the cylinder valve knob counter clockwise one turn to open.
Apply the leak-testing solution by spraying it on joints of the gas delivery system.
Blowing bubbles in the soap solution indicates that a leak is present.
Stop a leak by tightening the loose joint or by replacing the faulty part with a replacement part
recommended by the manufacturer. Do not attempt to repair the cylinder valve if it is
damaged. The cylinder must be discarded to a proper LP tank location and then replaced.
Turn all control knobs back to the full OFF position.
If you are unable to stop a leak turn all control knobs back to the full OFF position, shut off the
gas supply to the grill and release pressure in the hose and manifold by pushing in and
turning any of the control valves one quarter turn counter-clockwise.
On LP systems, remove the cylinder from the grill.
Call an authorized gas appliance service technician or an LP gas dealer.
Do not use the appliance until the leak is corrected.