Self-Contained Ice Maker User Manual for Installation and Maintenance
Instruction of Control Panel
1. LED Display:
Self-check Display “ini” code.
Preparing Counting seconds positively.
Ice making: Counting seconds positively
prior the water reaching 0 degree C.
Counting seconds down to 0 s after.
Ice Harvest: Counting seconds positively.
Clean: Display “CLE” during cleaning and
sterilizing;Display “rin” during rinsing.
2. LED Lamps: Lights on during the related
process.
3. Ice cube thickness adjustment: During the
ice making process, if you are not
satisfied with the ice thickness, press the
Ice cube “–” button for 3 seconds, then
click the button “+” or - on the panel to
adjust the thickness of ice cube.
Note: By clicking the “+” or -button
one time, the ice making time is extended
or shortened by 1.5 minutes.
4. Cleaning: During the normal operation,
hold the cleaning button for 3 seconds to
enter the cleaning process. During the
entire cleaning process, cleaning agents
and disinfectants need to be put into the
water trough. When the clean process is
finished, the ice maker will go to ice
making process.
5. Switch: When the device is powered, click
the “Switch” button to switch OFF/ON the
device.
6. Voice function (only for machines with
voice function): The machine with voice
announcement prompts will provide voice
prompts for related operations.
7. Please open and close the storage bin
door gently. Do not slam the door. After
taken the ice cubes, please close the
door.
8. If the ice maker is not in use for a long
time, it should be energized and run for 2
to 4 hours every 2 months.
Other special protection - shutdown
If the ice machine has not detected ice
cube falling off in three cycles, it will shut
down for safety protection. The ice maker
needs to be checked.
The ice machine detects that the ambient
temperature is too high and will stop for
safety protection.
If the water-cooled ice machine detects
an abnormity in water supply, it will stop
for safety protection.