7 Inspection Running
7.1 Things to check before inspection running:
1) Safety circuit/door interlock circuit are normal, DO NOT short door interlock!
2) After power on, KJT emergency stop contactor in control cabinet, KMB door interlock
contactor, KMC power contactor are closed, check if the controller is normal and parameter setting
is correct, in LCD indicator, elevator state is “INSP.
3) Connect the brake to control cabinet properly.
7.2 Inspection running
When the conditions for inspection running in machine room are satisfied, press the Jog
Up/Down button on the control cabinet, elevator will run up/down in set inspection speed. If car
running direction is opposite to inspection run button, correct this through F6-03. 0: traction sheaves
counterclockwise rotation & car run down; 1: traction sheaves clockwise rotation & car run up. Set
according to actual situation.