BL6-U Parallel Integrated Controller Quick Commissioning User Manual
5
CHART 2.1 Control Circuit Port definition and Function
Door inter-lock input + (110V-220VAC)
Door inter-lock input – (110V-220VAC)
KDY auxiliary contact output
KKM Door open 1 control output
KGM Door close 1 control output
KKM2 door open 2 control output
KGM2 door close 2 control output
Illumination switch-off output
Ea low 7 segment code a display
Eb low 7 segment code b display
Ec low 7 segment code c display
Ed low 7 segment code d display
Ee low 7 segment code e display
Ef low 7 segment code f display
Eg low 7 segment code g display
EHbc high 7 segment code bc display
(Inspection output when floor display is
not in 7-seg-code mode. when floor
display is in 7-seg-code mode, and the
high bit is not used, Inspection output
can be set by function code FU-05)
EHg high 7 segment code g display
Cut-off power after parking (disabled
output after parking)
FMQ buzzer control output
Cut main contactor output
SKYC door open delay input
Full Collective/Simplex Collective
Car call input 1/ Car call input 1
Full Collective/Simplex Collective
Car call input 2/ Car call input 2
Full Collective/Simplex Collective
Car call input 3/ Car call input 3