- 12 -
B.T.U. RATING REQUIREMENTS
These are the total approximate B.T.U. Ratings based on twelve inch cooking sections of unit. The gas line size must lie within compliance with
the state code 248CMR for the Commonwealth of Massachusetts.
Model Number Approximate BTU Line Size
RPB-30-IR 115,000 ½”
RPB-36-IR 125,000 ½”
RPB-48-IR 155,000 ½”
RPB-60-IR 215,000 ¾”
RPBGT-30 70,000 ½”
RPBGT-36 80,000 ½”
RPBGT-48 94,000 ½”
ALL RPB RANGES-COOKTOPS-INDOOR BBQ
DESCRIPTION NAT. ORIFICE SIZE L.P. ORIFICE SIZE
LISTED BTU
P/H
ACTUAL BTU P/H
FIXED OR
ADJUSTABLE
PRESSURE REG.NAT/LP
OPEN TOP BURNER LARGE # 48 P/N 709548 # 56 P/N 709956 18,000 15400/14,500 ADJ.
OPEN TOP BURNER SMALL # 51 P/N 709551 # 57 P/N 709957 14,500 15,400/14,500 ADJ.
SIMMER BURNER # 78 P/N 734678 # 87 P/N 734687 750 750/750 FIXED
GRIDDLE BURNER (U) # 51 P/N 709551 # 57 P/N 709957 15,000 15,400 /14,500 ADJ.
CHARBROILER BURNER (U) # 51 P/N 709551 # 57 P/N 709957 15,000 15,400/14,500 ADJ.
I.R. BROILER BURNER # 50 P/N 735550 # 56 P/N 735556 16,000 16,800/16,900 FIXED
OVEN BURNER-30/36" # 42 P/N 718701 ASY #52 P/N 718702 ASY 30,000 29,500/29,500 FIXED
OVEN BURNER-48" # 51 P/N 705401 # 57 P/N 705401 15,000 15,400/14,500 ADJ.
5"to 10" & 4" TO 10" REG.
P/N 718301 REQD. ON ALL
MODELS LISTED IN THIS
SECTION
INDOOR CHARBROILERS 15" AND 30" UNITS
DESCRIPTION NAT. ORIFICE SIZE L.P. ORIFICE SIZE
LISTED BTU
P/H
ACTUAL BTU P/H
FIXED OR
ADJUSTABLE
PRESSURE
REG.NAT/LP
CHARBROILER BURNER (U) # 51 P/N 709551 # 57 P/N 709557 20,000 15,400/14,500 ADJ.
REG. P/N 718301
REQD. ON ALL
MODELS LISTED IN
THIS SECTION
PRESTIGE SEALED-BURNER RANGES
DESCRIPTION NAT. ORIFICE SIZE L.P. ORIFICE SIZE
LISTED BTU
P/H
ACTUAL BTU P/H
FIXED OR
ADJUSTABLE
PRESSURE
REG.NAT/LP
LARGE BURNER #51 P/N 734651 # 57 P/N 734657 15,000 15400/14,500 FIXED
SMALL BURNER P/N 734657 #70 P/N 734670 6,000 6,350/6,000 FIXED
REG. P/N 718301
REQD. ON ALL
MODELS LISTED IN
THIS SECTION
OUTDOOR BBQ 27”, 36”, & 48” UNITS
DESCRIPTION NAT. ORIFICE SIZE L.P. ORIFICE SIZE
LISTED BTU
P/H
ACTUAL BTU P/H
FIXED OR
ADJUSTABLE
PRESSURE
REG.NAT/LP
H- BURNER #45 P/N 709545 #55 P/M 709555 20,000 20,500/21,200 FIXED
U- BURNER #45 P/N 709545 #55 P/M 709555 20,000 20,500/21,200 FIXED
ROTIS. IR BURNER- SM #54 P/N 709554 #65 P/M 709565 10,500 9,200/9,600 FIXED
ROTIS. IR BURNER- LG #51 P/N 709551 #59 P/M 709559 14,000 13,700/13,300 FIXED
OPEN TOP BURNER LARGE # 51 P/N 734651 # 57 P/N 734657 14,500 13,700/14,500 FIXED
SMOKER BURNER #63 P/N 707563 #72 P/N 709572 5,000 4,200/4,900 FIXED
REG. P/N 717301
4” NAT/10” LP
REQD. ON ALL
MODELS LISTED IN
THIS SECTION
Please Note!
The size of the LP supply tank should
be calculated by the total number of
BTU requirements of the gas
appliance.
The pressure supplied from the LP
supply tank should be between 11”
WCI and 13” WCI. The regulator on
your product will supply a steady 10”