EN11
Examples of rejection for substances which may be present in water
INORGANIC SUBSTANCES %
Turbidity (cloudiness) >99
Colour rating >99
Cations/Metals
Sodium >96 >92*
Potassium >97
Calcium (hardness) >99
Aluminium >99
Iron >99
Manganese >99
Cations/Heavy metals
Copper >99
Lead >99
Zinc >99
Mercury >99
Cadmium >99
Chrome >98
Nickel >99
Anions
Fluoride >99
Chloride >98 >95*
Nitrate >97
Sulphate >97
ORGANIC SUBSTANCES %
Hydrocarbons
Heptane, octane, decane, etc. >98
Benzene, toluene, xylene,
Ethyl benzene, etc. >99
Diesel oil >99
Polyaromatic hydrocarbons
PAH >99
Chlorinated hydrocarbons
Compounds which can form
when water is chlorinated >99
Trihalomethanes (THM)
Trichloromethane >60
Bromodichloromethane,
dibromochloromethane,
tribromomethane >99
Pesticides
PCB >99
MICRO-ORGANISMS
Heterotrophic bacteria >99
Coliform bacteria/E.Coli >99
TECHNICAL FACTS
* RO400B/RO400BC/RO400BCV
Sodium and chloride are not separated in the same extent because of the high salt content.
UNPACKING
If the appliance has been damaged during transportation,
you should immediately notify the company responsible for
delivering it.
Carefully lift out the water purifier by taking hold of the rear
handle and the front edge. The water purifier can be dam-
aged if it is lifted in any other way.
Check the purifier for any signs of damage and check that no
accessories are missing. Any damage, faults or missing parts
should be notified to the supplier immediately.
Do not leave packaging material lying around so that chil-
dren can play with it.
•
•
•
•
INSTALLATION
POSITIONING THE WATER PURIFIER
Remember the following when installing the water purifier:
The purifier is installed upright, without support, on a hori-
zontal surface that can take the load.
The installation space should be close to cold water supply,
drainage and an earthed electrical supply.
It should be easy to inspect the control panel.
It should be possible to open the front cover so that the filter
containers can be accessed.
The water purifier should be installed with a 2 cm gap to any
adjacent fittings or walls to ensure good ventilation around
the appliance.
Connections can be routed in any direction from the connec-
tion point. Make sure no connections are crushed or dam-
aged. Hoses and cables must not be tensioned. The dimen-
sions of the area required for the water purifier are specified
in FIG.7.
•
•
•
•
•
•