Errors on the power unit (displayed in red and blue)
"blue/blue/blue/red"
Error 8001 [0001]
The charging voltage cannot be switched on;
internal error or hardware defective:
Reconnect the vehicle or restart the Wallbox.
If the error occurs again, contact your service
outlet.
"blue/blue/blue/red"
Error 8005 [0101]
Residual current monitor:
An error was identified during the self-test or the
monitor has tripped as a result of an excessive
fault current.
Check your charging cable for signs of damage
or water accumulation in the plug. The monitor
may also trip due to a lightning strike in the
surrounding area.
"blue/red/red/red"
Error 8007 [0111]
Safety monitor:
A problem relating to the internal safety circuit
has been identified.
It is possible that the contacts on the charging
contactor can no longer be opened. In this state
the Wallbox cannot perform an automatic restart
attempt.
The Wallbox must be restarted at the mains.
In certain cases the error may relate to a problem
in this software. A software update may rectify
the error, see section entitled SOFTWARE
UPDATE.
If the device continues to display the error after
the software has been updated, please contact
your service partner.