BOGE Operating instructions for C 16 N...C 30 N, C 16 F N...C 30 F N series screw compressors Page 31
Installation 3.3 Installation
Fig. 3.4: Remove cladding
Fig. 3.5: Connect compressor
1 Electrical connection
2 Compressed air outlet
3 Condensate line dryer
WARNING!
To avoid damages to the cooler you must counter the screw connections at
the compressed air outlet with a spanner.