Installation, use and service manual

Questions and Answers

  • S
    Samantha TaylorAug 5, 2025
    Why is my BONFIGLIOLI 313 L bearing temperature too high?
    • C
      Cynthia ContrerasAug 6, 2025
      High bearing temperature in BONFIGLIOLI DC Drives can occur due to several reasons: * The oil level might be too low, in which case you should top up the oil level. * The oil might be spent, requiring replacement. * The bearings could be defective, in which case you should contact an authorized workshop.
  • B
    Brady BarnettAug 9, 2025
    What to do if my BONFIGLIOLI DC Drives gear unit does not run or runs with difficulty?
    • N
      Nancy ThompsonAug 9, 2025
      If your BONFIGLIOLI DC Drives gear unit isn't running smoothly, here's what could be happening: * The oil viscosity might be too high, requiring you to replace the oil, referring to the recommended lubricant chart. * The oil level might be too high, so you should check the oil level. * The load applied might be excessive, suggesting a redesign of the drive for the actual load required.
  • J
    John HamiltonAug 14, 2025
    Why is my BONFIGLIOLI DC Drives operating temperature too high?
    • J
      Jenna MelendezAug 14, 2025
      High operating temperatures in BONFIGLIOLI DC Drives can be attributed to: * The oil level being too high, so you should check the oil level. * The oil being spent, meaning it needs to be replaced. * Contaminants in the oil, indicating the oil should be replaced.
  • T
    Tyler TorresAug 19, 2025
    What causes abnormal running noise in BONFIGLIOLI 313 L DC Drives?
    • A
      Andrew SmithAug 19, 2025
      Abnormal running noise in your BONFIGLIOLI DC Drives can stem from several issues: * Damaged gears, defective or worn bearings, or excessive bearing axial backlash, all require contacting an authorized workshop. * Excessive load applied, which can be corrected by adjusting the load to the rated values in the Sales Catalogue. * Contaminant in oil, which means you should replace the oil.
  • V
    vpughAug 22, 2025
    What causes oil leaks in BONFIGLIOLI 313 L DC Drives?
    • J
      Jason ClineAug 22, 2025
      Oil leaks in BONFIGLIOLI DC Drives can be caused by: * Oil level being too high, so you should check the oil level. * Inadequate casing/coupling seals or worn gaskets, both require contacting an authorized workshop.
  • S
    Shane YoderAug 27, 2025
    What causes abnormal noise at gear unit mounting in BONFIGLIOLI 313 L DC Drives?
    • M
      Mark FinleyAug 27, 2025
      Abnormal noise at the gear unit mounting in BONFIGLIOLI DC Drives can occur if: * Mounting bolts are loose, so you should tighten bolts to the specified torque. * Mounting bolts are worn, so you should replace the bolts.
  • J
    Joanne JonesAug 31, 2025
    What to do if the output shaft does not turn with motor running in BONFIGLIOLI 313 L?
    • G
      gjonesSep 1, 2025
      If the output shaft of your BONFIGLIOLI DC Drives isn't turning while the motor is running, it could be due to damaged gears, which requires contacting an authorized workshop.

Summary

1.0 - GENERAL INFORMATION

1.1 - PURPOSE OF THE MANUAL

Manufacturer's manual provides information regarding safe transport, handling, installation, maintenance, repair, disassembly and dismantling of the gear unit.

1.2 - PRODUCT IDENTIFICATION

Information identifying the product is shown on its nameplate. Gearmotors have two nameplates.

3.0 - SAFETY INFORMATION

3.1 - SAFETY STANDARDS

Carefully read instructions, ensure trained personnel, use for permitted applications, and follow maintenance schedules.

5.0 - INSTALLATION

5.1 - Installing the Gear Unit

General procedures for installing the gear unit, including safety, preparation, and various mounting types.

5.5 - LUBRICATION

6.0 - TESTING THE GEAR UNIT

7.0 - USING THE EQUIPMENT

8.0 - MAINTENANCE

Safety Precautions for Maintenance

Steps to ensure safety during maintenance, including switching off power and environmental precautions.

Routine Maintenance Schedule

Schedule and actions for routine maintenance tasks based on frequency.

9.0 - REPLACING PARTS

10.0 - TROUBLESHOOTING

Common Faults and Remedies

Lists common faults like high temperature, noise, and oil leaks with their causes and remedies.

ANNEX 1 - CHECKING THE OIL LEVEL