29 OPERATING FAULTS
i28 : Core probe: Faulty or missing when
cooking starts
Cooking will not start To start cooking connect the probe or replace it if
necessary. Switch to timer mode if necessary. If the
problem persists, call your after sales service
E30 : Electronics overheating: (>70°C)
Cooking continues automatically at a
temperature below 180°C
Installation problem: check the proximity of a
heating unit to the right hand side.
If the problem persists, call your after sales service
E32 : Core probe: 2 sensors faulty
Cooking continues.
Replace the core probe as soon as possible
If the problem persists, call your after sales service
i33 : Core probe faulty or missing whilst
cooking
Cooking stops To continue cooking connect the probe or replace it
if necessary. Switch to timer mode if necessary. If
the problem persists, call your after sales service
i41 : Lack of water detected: water is not
flowing from the spout
Cooking continues.
A cleaning cycle stops (Paused) or
automatic filling
Check the water supply to the unit (Valve open,
pressure…).
If necessary, call your after sales service
E43 : Leak detected
Cooking continues.
Turn the water supply off and call your after sales
service
i49 : USB stick full or missing USB stick full or USB awaited Clear the USB stick or connect another one.
If the problem persists, call your after sales service
EFr : Well probe overheated Cooking stops Switch the appliance off and call your after sales
service
EFx : Well base overheated (x = Number of
the zone)
Cooking stops Switch the appliance off and call your after sales
service
ESx : Well base probe short circuit or
disconnected (x = Number of the
zone)
Cooking stops Switch the appliance off and call your after sales
service
ESb : Well base probe short circuit or
disconnected
Cooking stops Switch the appliance off and call your after sales
service
E72 : Electronics at > 85°C Cooking stops Installation problem: check the proximity of a
heating unit to the right hand side.
If the problem persists, call your after sales service
E90 : Detection of well tilt ram being
blocked
If the well can be returned to the horizontal
position the unit can be used for cooking
(without any movement of the well)
Something is jammed under the well preventing it
from moving: Clear it if you can.
If the problem persists, call your after sales service
E91 : Abnormal pressure detected Pressure mode deactivated Call your after sales service
E92 : Pressure sensor faulty Pressure mode deactivated.
If running in pressure mode cooking stops.
Cooking can only take place with the lid
open
Call your after sales service
E93 : Faulty safety contactor Cooking will not start Switch the appliance off and call your after sales
service
E95 : Safety pressostat (Bps) activated If the problem persists, call your after sales service