Control Panels Power supply | en 25
Bosch Security Systems, Inc. Installation Manual 2018.07 | 16 | F.01U.287.180
Notice!
Earth ground reference
Do not use telephone or electrical ground for the earth ground connection. Use 14 AWG (1.8
mm) to 16 AWG (1.5 mm) wire when making the connection
Use a grounding rod or a cold water pipe.
Run wire as close as possible to grounding device.
Callout á…³ Description
1 á…³ B520 Auxiliary Power Supply Module
2 á…³ 14 AWG - 16 AWG (1.8 mm - 1.5 mm) wire
3 á…³ Ground device (grounding rod or cold water pipe)
Wiring to the control panel
Notice!
Terminal wiring
Use the terminal strip labeled with PWR, A, B, and COM for SDI2 IN to wire to corresponding
control panel SDI2 terminals. Do not use interconnect wiring.
Use 12 AWG to 22 AWG (2.0 mm to 0.6 mm) wire.
SDI2 OUT
SDI2 IN
PWR A B COM PWR A B COM
1
2
3
R
Y
G
B
7 COM 8
C
OUTPUT
B
1 k End of Line Resistors
Voltage Ranges
ON-BOARD POINTS
3.7 - 5.0 VDC
2.0 - 3.0 VDC
0.0 - 1.3 VDC
Open
Normal
Short
3 COM 4 5 COM 61 COM 2
R Y G B
SDI2
Device Bus
AUX
- 12 V +
TMPR
1 COM 2 7 COM 83 COM 4 5 COM 6
RESET
COM AUX
R Y G B
PWR A B COM
B C
OUTPUT
Callout á…³ Description
1 á…³ Control panel
2 á…³ B520 Auxiliary Power Supply Module
3 á…³ Terminal strip wiring