Single Stage Heat Pump
Example: Bosch Inverter Ducted Split
Ensure the system has a C-wire
Ensure the pre-installed jumper wire remains between RH and R/RC
Connect the R, C, Y1, O/B and G wires from the heat pump to R/RC, C, Y,
O/B/W2 and G terminals on the wall plate, respectively
Single Stage Heat Pump
with Emergency Heat and Auxiliary Heat
Note: W/E/AUX controls both the Emergency Heat and Auxiliary Heat outputs.
Ensure the system has a C-wire
Ensure the pre-installed jumper wire remains between RH and R/RC
Connect the R, C, W1, Y1, O/B and G wires from the heat pump to R/RC,
C, W/E/AUX, Y, O/B/W2 and G terminals on the wall plate, respectively
Wiring Diagrams
R/RC
R/RC
R/RC
R/RC