    Richard HansenAug 2, 2025
    What to do if my Bosch CR 50 Thermostat hot water remains cold?
    • C
      cody05Aug 2, 2025
      If the hot water remains cold, check if the BUS cable was connected incorrectly. If there are wiring faults, rectify them and switch the controller off and on again.
  • M
    Michelle JacksonAug 7, 2025
    What to do if there is no communication via BUS interface EMS 2 on my Bosch CR 50?
    • C
      Carlos NewmanAug 7, 2025
      If there is no communication via the BUS interface EMS 2, check whether the BUS cable was connected incorrectly. Rectify any wiring faults and then switch the controller off and on again.
  • M
    mgomezAug 12, 2025
    Why does my Bosch Thermostat say 'Heating circuit flow temperature sensor faulty'?
    • G
      Gloria WilliamsAug 12, 2025
      The 'Heating circuit flow temperature sensor faulty' message may appear because of the configuration. The selected setting requires a flow temperature sensor. To resolve this, change the configuration.
  • R
    russellmanuelAug 16, 2025
    How to fix a faulty heating circuit flow temperature sensor on a Bosch Thermostat?
    • C
      christophergutierrezAug 16, 2025
      To fix a faulty heating circuit flow temperature sensor, check the flow temperature sensor according to the table. Then replace the sensor.
  • J
    Justin StoneAug 21, 2025
    What to do if system configuration not confirmed on Bosch Thermostat?
    • K
      Kimberly WillisAug 22, 2025
      If the system configuration is not confirmed, it means the system configuration was not completed. Configure the system completely and confirm.
  • M
    Michael BeckAug 27, 2025
    How to deactivate hot water system on Bosch CR 50 Thermostat?
    • M
      Mary BaxterAug 27, 2025
      To deactivate the hot water system, deactivate it in the service menu.

Summary

Key to symbols and safety instructions

Explanation of symbols

Keywords at the start of a warning indicate the type and seriousness of the ensuing risk.

General safety instructions

These operating instructions are intended for the heating system user. All instructions must be observed.

Product Description

Product data for energy consumption

The specified product data corresponds to the requirements of the EU Regulation No. 811/2013.

Overview of control elements and symbols

Operating the appliance

Changing the room temperature

Instructions on how to query and change the room temperature temporarily or permanently.

DHW settings

Settings for domestic hot water (DHW), including once-only cylinder charging.

Setting the time program

Guide to setting the time program for heating for several days or individual weekdays.

Setting up a holiday program

Instructions on how to set up and activate a holiday program.

More settings

Options for setting time, date, language, and display contrast.

Main menu

Heating menu

Contains time program settings for heating, including default settings and reset options.

DHW menu

Options for loading once, temperature, mode, recirculation, and disinfection of DHW.

Info menu

Displays current system values and active operating status for heating and DHW.

Settings menu

Options for language, date format, time format, temperature units, and contrast.

Faults

Old electrical and electronic appliances